Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Front Immunol ; 14: 1152522, 2023.
Article in English | MEDLINE | ID: covidwho-2280591

ABSTRACT

Introduction: Understanding how spike (S)-, nucleoprotein (N)-, and RBD-directed antibody responses evolved in mild and asymptomatic COVID-19 in Africa and their interactions with SARS-CoV-2 might inform development of targeted treatments and vaccines. Methods: Here, we used a validated indirect in-house ELISA to characterise development and persistence of S- and N-directed IgG, IgM, and IgA antibody responses for 2430 SARS-CoV-2 rt-PCR-diagnosed Ugandan specimens from 320 mild and asymptomatic COVID-19 cases, 50 uninfected contacts, and 54 uninfected non-contacts collected weekly for one month, then monthly for 28 months. Results: During acute infection, asymptomatic patients mounted a faster and more robust spike-directed IgG, IgM, and IgA response than those with mild symptoms (Wilcoxon rank test, p-values 0.046, 0.053, and 0.057); this was more pronounced in males than females. Spike IgG antibodies peaked between 25 and 37 days (86.46; IQR 29.47-242.56 BAU/ml), were significantly higher and more durable than N- and RBD IgG antibodies and lasted for 28 months. Anti-spike seroconversion rates consistently exceeded RBD and nucleoprotein rates. Spike- and RBD-directed IgG antibodies were positively correlated until 14 months (Spearman's rank correlation test, p-values 0.0001 to 0.05), although RBD diminished faster. Significant anti-spike immunity persisted without RBD. 64% and 59% of PCR-negative, non-infected non-contacts and suspects, exhibited baseline SARS-CoV-2 N-IgM serological cross-reactivity, suggesting undetected exposure or abortive infection. N-IgG levels waned after 787 days, while N-IgM levels remained undetectable throughout. Discussion: Lower N-IgG seroconversion rates and the absence of N-IgM indicate that these markers substantially underestimate the prior exposure rates. Our findings provide insights into the development of S-directed antibody responses in mild and asymptomatic infections, with varying degrees of symptoms eliciting distinct immune responses, suggesting distinct pathogenic pathways. These longer-lasting data inform vaccine design, boosting strategies, and surveillance efforts in this and comparable settings.


Subject(s)
COVID-19 , Male , Female , Humans , COVID-19/diagnosis , SARS-CoV-2 , Uganda/epidemiology , Antibodies, Viral , Immunoglobulin G , Immunoglobulin M , Immunoglobulin A
2.
PLoS One ; 17(5): e0265334, 2022.
Article in English | MEDLINE | ID: covidwho-1833638

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda. METHODS: This was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs. Test sensitivity and specificity were generated by comparing results against qRT-PCR results (Berlin Protocol) at a cycle threshold (Ct) cut-off of ≤39. Sensitivity was also calculated at Ct cut-offs ≤29 and ≤33. RESULTS: None of the Ag RDTs had a sensitivity of ≥80% at Ct cut-off values ≤33 and ≤39. Two kits, Panbio™ COVID-19 Ag and VivaDiag™ SARS-CoV-2 Ag had a sensitivity of ≥80% at a Ct cut-off value of ≤29. Four kits: BIOCREDIT COVID -19 Ag, COVID-19 Ag Respi-Strip, MEDsan® SARS-CoV-2 Antigen Rapid Test and Panbio™ COVID-19 Ag Rapid Test had a specificity of ≥97%. CONCLUSIONS: This evaluation identified one Ag RDT, Panbio™ COVID-19 Ag with a performance at high viral load (Ct value ≤29) reaching that recommended by WHO. This kit was recommended for screening of patients with COVID -19-like symptoms presenting at health facilities.


Subject(s)
COVID-19 , SARS-CoV-2 , Antigens, Viral/analysis , COVID-19/diagnosis , Cross-Sectional Studies , Diagnostic Tests, Routine , Humans , Prospective Studies , Sensitivity and Specificity , Uganda/epidemiology
3.
Emerg Infect Dis ; 28(5): 1021-1025, 2022 05.
Article in English | MEDLINE | ID: covidwho-1760189

ABSTRACT

Genomic surveillance in Uganda showed rapid replacement of severe acute respiratory syndrome coronavirus 2 over time by variants, dominated by Delta. However, detection of the more transmissible Omicron variant among travelers and increasing community transmission highlight the need for near-real-time genomic surveillance and adherence to infection control measures to prevent future pandemic waves.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/epidemiology , Humans , Pandemics , SARS-CoV-2/genetics , Uganda/epidemiology
4.
BMC Infect Dis ; 22(1): 174, 2022 Feb 21.
Article in English | MEDLINE | ID: covidwho-1700789

ABSTRACT

BACKGROUND: Globally, key subpopulations such as healthcare workers (HCW) may have a higher risk of contracting SARS-CoV-2. In Uganda, limited access to Personal Protective Equipment and lack of clarity on the extent/pattern of community spread may exacerbate this situation. The country established infection prevention/control measures such as lockdowns and proper hand hygiene. However, due to resource limitations and fatigue, compliance is low, posing continued onward transmission risk. This study aimed to describe extent of SARS-CoV-2 seroprevalence in selected populations within the Rakai region of Uganda. METHODS: From 30th November 2020 to 8th January 2021, we collected venous blood from 753 HCW at twenty-six health facilities in South-Central Uganda and from 227 population-cohort participants who reported specific COVID-19 like symptoms (fever, cough, loss of taste and appetite) in a prior phone-based survey conducted (between May and August 2020) during the first national lockdown. 636 plasma specimens collected from individuals considered high risk for SARS-CoV-2 infection, prior to the first confirmed COVID-19 case in Uganda were also retrieved. Specimens were tested for antibodies to SARS-CoV-2 using the CoronaChek™ rapid COVID-19 IgM/IgG lateral flow test assay. IgM only positive samples were confirmed using a chemiluminescent microparticle immunoassay (CMIA) (Architect AdviseDx SARS-CoV-2 IgM) which targets the spike protein. SARS-CoV-2 exposure was defined as either confirmed IgM, both IgM and IgG or sole IgG positivity. Overall seroprevalence in each participant group was estimated, adjusting for test performance. RESULTS: The seroprevalence of antibodies to SARS-CoV-2 in HCW was 26.7% [95%CI: 23.5, 29.8] with no difference by sex, age, or cadre. We observed no association between PPE use and seropositivity among exposed healthcare workers. Of the phone-based survey participants, 15.6% [95%CI: 10.9, 20.3] had antibodies to SARS-CoV-2, with no difference by HIV status, sex, age, or occupation. Among 636 plasma specimens collected prior to the first confirmed COVID-19 case, 2.3% [95%CI: 1.2, 3.5] were reactive. CONCLUSIONS: Findings suggest high seroprevalence of antibodies to SARS-CoV-2 among HCW and substantial exposure in persons presenting with specific COVID-19 like symptoms in the general population of South-Central Uganda. Based on current limitations in serological test confirmation, it remains unclear whether seroprevalence among plasma specimens collected prior to confirmation of the first COVID-19 case implies prior SARS-CoV-2 exposure in Uganda.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Communicable Disease Control , Health Personnel , Humans , Seroepidemiologic Studies , Uganda/epidemiology
5.
Int J Infect Dis ; 112: 281-287, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1654535

ABSTRACT

INTRODUCTION: Serological testing is needed to better understand the epidemiology of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) virus. Rapid diagnostic tests (RDTs) have been developed to detect specific antibodies, IgM and IgG, to the virus. The performance of 25 of these RDTs was evaluated. METHODS: A serological reference panel of 50 positive and 100 negative plasma specimens was developed from SARS-CoV-2 PCR and antibody positive patients and pre-pandemic SARS-CoV-2-negative specimens collected in 2016. Test performance of the 25 RDTs was evaluated against this panel. RESULTS: A total of 10 RDTs had a sensitivity ≥98%, while 13 RDTs had a specificity ≥98% to anti-SARS-CoV-2 IgG antibodies. Four RDTs (Boson, MultiG, Standard Q, and VivaDiag) had both sensitivity and specificity ≥98% to anti-SARS-CoV-2 IgG antibodies. Only three RDTs had a sensitivity ≥98%, while 10 RDTs had a specificity ≥98% to anti-SARS-CoV-2 IgM antibodies. Three RDTs (Autobio, MultiG, and Standard Q) had sensitivity and specificity ≥98% to combined IgG/IgM. The RDTs that performed well also had perfect or almost perfect inter-reader agreement. CONCLUSIONS: This evaluation identified three RDTs with a sensitivity and specificity to IgM/IgG antibodies of ≥98% with the potential for widespread antibody testing in Uganda.


Subject(s)
COVID-19 , SARS-CoV-2 , Academies and Institutes , Antibodies, Viral , Diagnostic Tests, Routine , Humans , Immunoglobulin M , Sensitivity and Specificity , Uganda/epidemiology
6.
J Clin Microbiol ; 59(7): e0083721, 2021 06 18.
Article in English | MEDLINE | ID: covidwho-1486488

ABSTRACT

We assessed the performance of the CoronaCHEK lateral flow assay on samples from Uganda and Baltimore to determine the impact of geographic origin on assay performance. Plasma samples from severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) PCR-positive individuals (Uganda, 78 samples from 78 individuals, and Baltimore, 266 samples from 38 individuals) and from prepandemic individuals (Uganda, 1,077, and Baltimore, 532) were evaluated. Prevalence ratios (PR) were calculated to identify factors associated with a false-positive test. After the first positive PCR in Ugandan samples, the sensitivity was 45% (95% confidence interval [CI], 24,68) at 0 to 7 days, 79% (95% CI, 64 to 91) at 8 to 14 days, and 76% (95% CI, 50 to 93) at >15 days. In samples from Baltimore, sensitivity was 39% (95% CI, 30 to 49) at 0 to 7 days, 86% (95% CI, 79 to 92) at 8 to 14 days, and 100% (95% CI, 89 to 100) at 15 days after positive PCR. The specificity of 96.5% (95% CI, 97.5 to 95.2) in Ugandan samples was significantly lower than that in samples from Baltimore, 99.3% (95% CI, 98.1 to 99.8; P < 0.01). In Ugandan samples, individuals with a false-positive result were more likely to be male (PR, 2.04; 95% CI, 1.03,3.69) or individuals who had had a fever more than a month prior to sample acquisition (PR, 2.87; 95% CI, 1.12 to 7.35). Sensitivity of the CoronaCHEK was similar in samples from Uganda and Baltimore. The specificity was significantly lower in Ugandan samples than in Baltimore samples. False-positive results in Ugandan samples appear to correlate with a recent history of a febrile illness, potentially indicative of a cross-reactive immune response in individuals from East Africa.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , Female , Humans , Male , Sensitivity and Specificity , Uganda
7.
Int J Infect Dis ; 104: 282-286, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-898982

ABSTRACT

OBJECTIVES: There is a high demand for SARS-CoV-2 testing to identify COVID-19 cases. Real-time quantitative PCR (qRT-PCR) is the recommended diagnostic test but a number of constraints prevent its widespread implementation, including cost. The aim of this study was to evaluate a low cost and easy to use rapid antigen test for diagnosing COVID-19 at the point of care. METHODS: Nasopharyngeal swabs from suspected COVID-19 cases and low-risk volunteers were tested with the STANDARD Q COVID-19 Ag Test and the results were compared with the qRT-PCR results. RESULTS: In total, 262 samples were collected, including 90 qRT-PCR positives. The majority of samples were from males (89%) with a mean age of 34 years and only 13 (14%) of the positives were mildly symptomatic. The sensitivity and specificity of the antigen test were 70.0% (95% confidence interval (CI): 60-79) and 92% (95% CI: 87-96), respectively, and the diagnostic accuracy was 84% (95% CI: 79-88). The antigen test was more likely to be positive for samples with qRT-PCR Ct values ≤29, with a sensitivity of 92%. CONCLUSIONS: The STANDARD Q COVID-19 Ag Test performed less than optimally in this evaluation. However, the test may still have an important role to play early in infection when timely access to molecular testing is not available but the results should be confirmed by qRT-PCR.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , SARS-CoV-2/immunology , Adult , COVID-19/virology , Female , Humans , Male , Nasopharynx/virology , Point-of-Care Systems , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Sensitivity and Specificity , Uganda
SELECTION OF CITATIONS
SEARCH DETAIL